Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
The Correlation Between Immediate Implant Insertion Torque and Implant Stability Quotient
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 36 , Issue 6
November/December 2016

Pages 833–840


The Correlation Between Immediate Implant Insertion Torque and Implant Stability Quotient

Barry P. Levin, DMD


PMID: 27740644
DOI: 10.11607/prd.2865

Different parameters can be measured during dental implant insertion to determine the primary stability of the implant. The purpose of this retrospective study was to investigate whether a correlation exists between immediate implant insertion torque value (ITV) and implant stability quotient (ISQ) in nonmolar sites. A total of 59 implants in 52 patients were placed into extraction sockets. ITV was recorded at surgery, and ISQ was recorded at surgery and at followup. Implants with higher ITV and/or ISQ were evaluated at 6 to 8 weeks. An additional 4 to 6 weeks was permitted for implants with lower initial stability values. A nonsignificant correlation coefficient of 0.06 could be found between the measurements at either time point. The data suggests that there is no linear correlation between ITV and ISQ in the measured population. The findings of this study question the requirement of excessively high ITV and ISQ for immediate temporization and as prerequisites for successful osseointegration.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help